首页
期刊简介
编 委 会
期刊订阅
百年学会 医星璀璨
名院风范
学科风华
菁英风采
投稿须知
过刊浏览
联系我们
篇名
关键词
作者
作者单位
摘要
关键词
注册本刊作者
作者投稿查稿
专家远程审稿
编辑在线审稿
编务办公专区
主编办公专区
下载文档
《上海医学》审稿费代缴委托书
《上海医学》杂志2025年征订启事
《上海医学》期刊编审系统审稿专家使用手册
工作动态
01-03
《上海医学》杂志2025年度“春蕾杯”论文评比征文通知
03-05
《上海医学》杂志2024年度“春蕾杯”论文评比征文通知
06-14
创新驱动,培育人才—《上海医学》2021年度春蕾计划评审结果揭晓
01-21
《上海医学》期刊影响力指标和学科排名取得显著提升
01-20
《上海医学》恭祝大家新年快乐!
联系方式
发行周期:
月刊
主管单位:
上海市卫生健康委员会
主办单位:
上海市医学会
编辑出版:
《上海医学》编辑部
联系地址:
上海市北京西路1623号
邮编:
200040
电话:
021-62178606
传真:
021-62178606
邮箱:
smasmj@shsma.org.cn
ISSN:
ISSN0253-9934
CN:
CN31-1366/R
收款账号:
1001255309008900719
账户名:
上海市医学会
开户行:
工商银行上海市静安寺支行
友情链接
上海市医学会
当前位置:首页 >
超声引导下颈内静脉置管的临床研究
浏览(1123) 下载(0)
DOI:
作者:
岑奕
cenyi
作者单位:
411医院
411hospital
关键词:
超声检查;颈静脉;置管
摘要:
穿刺,B组超声定位后穿刺,C组超声全程引导下穿刺。记 录各组穿刺成功率、首次穿刺成功率、平均穿刺次数、成功置管平均所需时间、各种并发症(血肿、刺破动脉、气胸等)。结果 B、C组穿刺成功率(100%、100%)明显高于A组(P
A clinical study of cannulation of the internal jugular Vein with ultrasound guidance CEN Yi, XIA Jianhua,Wang Xi’an, et al. Department of Anesthesiology,NO.411 hospital of PLA ,Shanghai 200081, China 【Abstract】 Objective To Evaluate the utilization and effect of ultrasound scanner in percutaneous cannulation of the internal jugular vein for adult patients.Methods 120 patients undergoing elective surgery for digestive tumor were randomized into three groups. In the AL(anatomical landmark )group, the landmark for cannulation was the palpation of the common carotid pulsation or the sternocleidomastoid triangle. In the UL(ultrasound prelocation) group, the central vein was located by 2D-ultrasonic imaging. In UD(ultrasound guidance) group ,the cannulation was conducted by ultrasound all the time. Success rate, once success rate, the number of cannulation attempts, operation time and complications (hematoma, artery puncture, pneumothorax) were recorded. Result Compared with AL group, success rate in UL and UD group were increased significantly. The cannulation success rate in UL and UD group on once time were (85%) and (97.5%) respectively, which was better than that in AL group (60%) obviously (p<0.05). The number of cannulation attempts in UL,UD group are less than that in AL group (p<0.05). Operation time in UL and UD group were less than that in AL group distinctly (p<0.05). There were no complications except AL group (3 cases of hematoma, 4 cases of artery puncture). Conclusion Ultrasound-guided cannulation of internal jugular vein is good for increasing success rate and reducing the complications relatively. It’s a valuable approach for internal jugular vein cannulation. 【Key words】Ultrasonography; Jugular Veins;Catheterization
点击下载DOC全文